Sign In | Join Free | My himfr.com
Home > Centrifugal Chiller >

PID Control Water Cooled Falling Film Centrifugal Chiller With Directly Start

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Contact Now
    Buy cheap PID Control Water Cooled Falling Film Centrifugal Chiller With Directly Start from wholesalers
     
    Buy cheap PID Control Water Cooled Falling Film Centrifugal Chiller With Directly Start from wholesalers
    • Buy cheap PID Control Water Cooled Falling Film Centrifugal Chiller With Directly Start from wholesalers

    PID Control Water Cooled Falling Film Centrifugal Chiller With Directly Start

    Ask Lasest Price
    Brand Name : EuroKlimat
    Model Number : EKDC
    Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Price : Negotiation
    Payment Terms : T/T or L/C
    Supply Ability : 100pcs per month
    Delivery Time : 60 working days after received your payment
    • Product Details
    • Company Profile

    PID Control Water Cooled Falling Film Centrifugal Chiller With Directly Start

    High Efficiency Water-cooled Falling Film Centrifugal Chiller


    Specifications:


    EKDC500~850

    Model EKDC500EKDC550EKDC600EKDC650EKDC700EKDC750EKDC800EKDC850
    Nominal CoolingCooling CapacityU.S.RT510561612663714765816867
    kW17931972215223312510269028693048
    x104kCal/h154170185200216231247262
    Input PowerkW293321351381409437469497
    COPkW / kW6.126.146.136.126.146.166.126.13
    Chilled Water Flowm3/h308339370401432463493524
    Chilled Water Pressure DropkPa6261747373849096
    Cooling Water Flowm3/h359394431466502538574610
    Cooling Water Pressure DropkPa6866777677889698
    Cooling*Cooling CapacityU.S.RT498547597647697746796846
    kW17501925210022752450262528002975
    x104kCal/h151166181196211226241256
    Input PowerkW303332363394423451484513
    COPkW / kW5.785.805.795.775.795.825.795.80
    Chilled Water Flowm3/h301331361391421452482512
    Chilled Water Pressure DropkPa5958706969808692
    Cooling Water Flowm3/h353388424459494529565600
    Cooling Water Pressure DropkPa6664757475859395
    CompressorType Two Stage Semi-hermetic Centrifugal
    Start Type Y-Δ(Low Voltage)/ Directly(High Voltage)
    Power Supply 380V/3N~/50Hz380V/3N~/50Hz 6kV,10kV/3~/50Hz
    CondenserType Shell-Tube
    Qty. 11111111
    EvaporatorType Spray
    Qty. 11111111
    Refrigerant R134a
    Control Type Water Temp. PID Control
    Chilled Water Pipe SizeDN250250250250250250300300
    Cooling Water Pipe SizeDN250250250250250250300300
    Insulation Material Rubber flexible closed foam insulation materials
    Unit Net Weightkg91009600101001060011200112001180011800
    Operating Weightkg1005010550111001170012350123501310013100
    Rated Current
    (Nominal Cooling)
    380VA518570661729802854853905
    6kVA------5458
    10kVA------3234
    Rated Current
    (Cooling*)
    380VA536590684754829881880934
    6kVA------5660
    10kVA------3335
    Starting Current380VA28352835290231193308330837803780
    6kVA------299299
    10kVA------193193

    Note:
    ■ Nominal cooling conditions: Chilled water entering/leaving Temp.:12/7℃,cooling water entering/leaving Temp.:30/35℃;
    ■ Cooling* conditions :Chilled water entering/leaving Temp.:12/7℃,cooling water entering/leaving Temp.:32/37℃;
    ■ Water side standard bearing pressure 1.0MPa;
    ■ Above evaporator and condenser water side pressure drop not including external water pipe and the other parts resistance;
    ■ Evaporator and condenser water pipe is flange connection;
    ■ Refer to unit nameplate or manual for job site power supply arrangement.


    EKDC900~1500


    Model EKDC900EKDC950EKDC1000EKDC1100EKDC1200EKDC1300EKDC1400EKDC1500
    Nominal CoolingCooling CapacityU.S.RT917968101911211223132514271529
    kW32263406358539444302466150195378
    x104kCal/h277293308339370401432463
    Input PowerkW529554586646698760822879
    COPkW / kW6.106.156.126.116.166.136.116.12
    Chilled Water Flowm3/h555586617678740802863925
    Chilled Water Pressure DropkPa9097909495959698
    Cooling Water Flowm3/h64668171778986093210051076
    Cooling Water Pressure DropkPa9598959897989898
    Cooling*Cooling CapacityU.S.RT89594599510941194129313931492
    kW31493324349938494199454948995249
    x104kCal/h271286301331361391421451
    Input PowerkW546572605667721785849908
    COPkW / kW5.775.815.785.775.825.795.775.78
    Chilled Water Flowm3/h542572602662722782843903
    Chilled Water Pressure DropkPa8692869090909293
    Cooling Water Flowm3/h6366707067778469179891059
    Cooling Water Pressure DropkPa9295929594959595
    CompressorType Two Stage Semi-hermetic Centrifugal
    Start Type Y-Δ(Low Voltage)/ Directly(High Voltage)
    Power Supply 380V/3N~/50Hz 6kV,10kV/3~/50Hz6kV,10kV/3~/50Hz
    CondenserType Shell-Tube
    Qty. 11111111
    EvaporatorType Spray
    Qty. 11111111
    Refrigerant R134a
    Control Type Water Temp. PID Control
    Chilled Water Pipe SizeDN300300300350350350350350
    Cooling Water Pipe SizeDN300300300350350350350350
    Insulation Material Rubber flexible closed foam insulation materials
    Unit Net Weightkg1250012500132001450015500165001800018000
    Operating Weightkg1400014000148001635017500186002000020000
    Rated Current
    (Nominal Cooling)
    380VA94999510761120----
    6kVA61636870768797104
    10kVA3637404346525963
    Rated Current
    (Cooling*)
    380VA979102711111156----
    6kVA636570727990100107
    10kVA3738414448546165
    Starting Current380VA4489448950095670----
    6kVA355355397449494524555555
    10kVA230230256290319338359359

    Note:
    ■ Nominal cooling conditions: Chilled water entering/leaving Temp.:12/7℃,cooling water entering/leaving Temp.:30/35℃;
    ■ Cooling* conditions :Chilled water entering/leaving Temp.:12/7℃,cooling water entering/leaving Temp.:32/37℃;
    ■ Water side standard bearing pressure 1.0MPa;
    ■ Above evaporator and condenser water side pressure drop not including external water pipe and the other parts resistance;
    ■ Evaporator and condenser water pipe is flange connection;
    ■ Refer to unit nameplate or manual for job site power supply arrangement.


    Description:


    EKDC Series Centrifugal Chiller


    EKDC series water-cooled falling film centrifugal chiller adhering to energy saving and environmental protection of the brand concept, can provide chilled water for central air conditioning system in hotel, hospital, pharmaceutical, theater, stadium, recreation center, commercial building, office building, industrial and mining enterprises; also can for textile, chemical, food and electronic research to provide chilled water for process usage.

    Features

    Environment Friendly Refrigerant

    R134a is environment friendly refrigerant, zero ozone depletion, safety & non-poison, un-burnable, green & environment friendly, comply with current development trend of international environmental protection


    High Efficiency two-stage Compression Design

    Using high efficiency two-stage hermetic impeller compression increases efficiency more than 6%, lower relative speed, lower noise level, small vibration, higher reliability. Adopting three-dimensional flow high efficiency aluminum hermetic impeller design, greatly decrease air leakage; five-axis machining with higher precision, so can effective reduce impeller axis loss and separate loss, and greatly increase impeller efficiency. Than unit efficiency is better than national standards for energy conservation.


    Reliable Oil Recovery Device-Induced Jet Pump

    Through induced jet pump, on the condition of no energy loss make use of middle pressure steam flashing to achieve low pressure side oil recovery function.


    Refrigerant Flow Control Kit-Orifice Plate

    • Use orifice plate to control refrigerant flow. Each set orifice plate is designed and produced according to Centrifugal Chiller performance; so that can get the best match.

    • Orifice plate without any moving part, so that it is more reliable than the other throttle valves that need mechanical transmission


    Spray Type (Falling Film) Evaporator

    • The refrigerant into the evaporator is a heat exchange tube array on the spray direction. The liquid refrigerant in the tube wall to form a thin film flow down, also known as the falling film evaporator. Because only in the surface of the heat exchanger tube is covered with a layer of liquid refrigerant film, so the heat transfer effect is excellent

    • Using refrigerant circulation pump as the refrigerant throttling device from economizer to the evaporator, meanwhile pump out liquid refrigerant in evaporator bottom for recycling; in order to improve the refrigerant supply for evaporator upper copper pipe, so that can make sure that all copper pipes are covered by liquid refrigerant. Unit no need precise water level correction, only for general positioning, evaporator can play high normal performance.

    • Only evaporator bottom has a small amount of liquid refrigerant so that refrigerant charge is less, complying with environment protection.

    • After a large amount of refrigerant evaporation, lubrication oil concentrate in evaporator bottom; and then oil pump can draw out lubrication oil smoothly and then oil back to compressor oil groove.


    High Efficiency Advanced Centrifugal Compressor

    Centrifugal compressor has two-stage compression, internal using high strength alloy main shaft and hermetic impeller, using high precision gear, using non-flat high strength ball/roller bearing; so that emergency stop is ok. Unit start interval can be shortened to 10 minutes, and bearing life can up to 80000 hours.


    High Efficiency Condenser

    Condenser is divided into two parts, guide plate installed in the middle that can guide liquid refrigerant to the shell edge, can greatly improve lower copper pipe heat exchange efficiency. For large tonnage unit, this design is very effective, can reduce condensing Temp. 0.5~1℃.


    Authority Certificate

    We have industry’s most advanced test room for centrifugal chiller, this test room has passed China National Accreditation Committee audit qualification (CNAS L5123), strictly complying with GB/T10870-2001, GB/T18430.1-2007; testing capacity up to 3000RT. Before delivery, each unit has done strict full performance test to ensure unit performance.


    Advanced Control

    • Micro Computer Control

    • Touch Screen Panel

    • PID Control

    • Perfect Protection Function

    • Multiple Anti Surge Function

    • Reserve Connecting Port for Use


    Applications:

    Hotel, Hospital, Pharmaceutical, Theater, Stadium, Recreation Center, Commercial Building, Office Building, Industrial & Mining Enterprises, Textile, Chemical, Food and Electronic Research.


    Quality PID Control Water Cooled Falling Film Centrifugal Chiller With Directly Start for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)