R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Contact Now
    Buy cheap R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons from wholesalers
     
    Buy cheap R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons from wholesalers
    • Buy cheap R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons from wholesalers
    • Buy cheap R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons from wholesalers

    R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons

    Ask Lasest Price
    Brand Name : EuroKlimat
    Model Number : EKAS
    Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Price : Negotiation
    Payment Terms : T/T or L/C
    Supply Ability : 500pcs per month
    Delivery Time : 10 working days after received your payment
    • Product Details
    • Company Profile

    R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons


    R407C Screw type air cooled (heat pump) partial heat recovery unit 85 - 470 tons


    Specifications


    Model 

    EKAS

    085

    EKAS

    095

    EKAS

    115

    EKAS

    125

    EKAS

    140

    EKAS

    150

    EKAS

    165

    EKAS

    180

    Nominal cooling capacitykW284.1328.3388.0410.3473.7509.4557.3601.0
    USRT80.893.3110.3116.7134.7144.8158.5170.9
    ×104kcal/h24.428.233.435.340.743.847.951.7
    Nominal heating capacity*kW322.7354.7426.9431.3491.6528.6578.4623.7
    USRT91.8100.9121.4122.6139.8150.3164.4177.3
    ×104kcal/h27.830.536.737.142.345.549.753.6
    Partial heat recovery capacitykW71.082.197.0102.6118.4127.3139.3150.2
    ×104kcal/h6.17.18.38.810.211.012.012.9
    Cooling compressor powerkW93.1101.3123.9128.6146.1157.0171.4182.0
    Heating compressor powerkW95.8104.1124.1135.1153.4164.8179.9189.6
    Capacity modulation 25% ~ 100% stepless modulation
    Startup type Y-Δ
    Power supply 380V/3~/50Hz
    RefrigerantType R407C
    Circuit Qty. 11111111
    Control mode Electronic expansion valve
    CompressorType Semi-closed double screw type
    Qty. 11111111
    LubricantCode EK02
    Filling quantity 13x113x113x113x119x119x123x123x1
    FanType Spiral axial fan
    Qty.No.688810101212
    CapacitykW10.814.414.414.418.018.021.621.6
    Air flow×104m3/h1216161620202424
    Air side heat exchangerType Fins
    Densitypiece/inch16FPI
    Water side heat exchangerType Dry shell-tube type
    Water flow for coolingm3/h48.956.566.770.681.587.695.9103.4
    Pressure drop of cooling waterkPa5862736466615156
    Water flow for heating*m3/h55.561.073.474.284.690.999.5107.3
    Pipe diameterinch45555888
    Heat exchanger at the heat
    recovery side
    Type Plate heat exchanger
    Water flowm3/h12.214.116.717.620.421.924.025.8
    Pipe diameterinch22222222
    Rated currentA185207246254292311344362
    Startup currentA250278326338388413455480
    Max. startup currentA357357478478660660749749
    DimensionsLengthmm32004100410041005000500059005900
    Widthmm22602260226022602260226022602260
    Heightmm25252525252525252525252525252525
    Weight of a single indoor unitShipment of cooling only unitskg38654015416547654810481053805500
    Operation of cooling only unitskg40154165431549154966496655405660
    Shipment of heat pump unitskg39504100425048504900490054805600
    Operation of heat pump unitskg41004250440050005056505656405760


    Model 

    EKAS

    190

    EKAS

    200

    EKAS

    210

    EKAS

    225

    EKAS

    235

    EKAS

    250

    EKAS

    275

    EKAS

    300

    Nominal cooling capacitykW636.4683.3728.2797.2819.9820.6919.71018.7
    USRT181.0194.3207.1226.7233.1233.3261.5289.7
    ×104kcal/h54.758.862.668.670.570.679.187.6
    Nominal heating capacity*kW660.5709.1749.9813.3838.6862.7959.91057.2
    USRT187.8201.6213.2231.2238.4245.3272.9300.6
    ×104kcal/h56.861.064.569.972.174.282.690.9
    Partial heat recovery capacitykW159.1170.8182.1199.3205.0205.2229.9254.7
    ×104kcal/h13.714.715.717.117.617.619.821.9
    Cooling compressor powerkW192.8206.9207.8221.3227.4257.2285.6314.1
    Heating compressor powerkW200.8215.1214.2226.6232.4270.2299.9329.6
    Capacity modulation 25% ~ 100% stepless modulation12.5%~100% stepless modulation
    Startup type Y-Δ
    Power supply 380V/3~/50Hz
    RefrigerantType R407C
    Circuit Qty. 11111222
    Control mode Electronic expansion valve
    CompressorType Semi-closed double screw type
    Qty. 11111222
    LubricantCode EK02
    Filling quantity 23x123x123x123x123x113x219+1319x2
    FanType Spiral axial fan
    Qty.No.1214141616161820
    CapacitykW21.625.225.228.828.828.832.436.0
    Air flow×104m3/h2428283232323640
    Air side heat exchangerType Fins
    Densitypiece/inch16FPI
    Water side heat exchangerType Dry shell-tube type
    Water flow for coolingm3/h109.5117.5125.3137.1141.0141.2158.2175.2
    Pressure drop of cooling waterkPa4351567344455364
    Water flow for heating*m3/h113.6122.0129.0139.9144.2148.4165.1181.8
    Pipe diameterinch88888888
    Heat exchanger at the heat
    recovery side
    Type Plate heat exchanger
    Water flowm3/h27.429.431.334.335.335.339.543.8
    Pipe diameterinch22222222
    Rated currentA381413415446457508565622
    Startup currentA505548549590594676751826
    Max. startup currentA882882882882882732931931
    DimensionsLengthmm59006800680077007700810090009900
    Widthmm22602260226022602260226022602260
    Heightmm25252525252525252525252525252525
    Weight of a single indoor unitShipment of cooling only unitskg55205555575558055835958096759670
    Operation of cooling only unitskg56805715593559856015988099879982
    Shipment of heat pump unitskg56205670587059205950975098509850
    Operation of heat pump unitskg57805830605061006130100501016210162

    Model EKAS330EKAS360EKAS380EKAS400EKAS420EKAS445EKAS470
    Nominal cooling capacitykW1110.31201.91284.31366.61456.41548.11639.7
    USRT315.7341.7365.2388.6414.1440.2466.2
    ×104kcal/h95.5103.4110.4117.5125.3133.1141.0
    Nominal heating capacity*kW1152.21247.31332.71418.21499.81588.51677.3
    USRT327.6354.6378.9403.2426.4451.7476.9
    ×104kcal/h99.1107.3114.6122.0129.0136.6144.2
    Partial heat recovery capacitykW277.6300.5321.1341.6364.1387.0409.9
    ×104kcal/h23.925.827.629.431.333.335.3
    Cooling compressor powerkW339.0364.0388.9413.8415.6435.2454.8
    Heating compressor powerkW354.4379.2404.7430.3428.4446.6464.9
    Capacity modulation 12.5%~100% stepless modulation
    Startup type Y-Δ
    Power supply 380V/3~/50Hz
    RefrigerantType R407C
    Circuit Qty. 2222222
    Control mode Electronic expansion valve
    CompressorType Semi-closed double screw type
    Qty. 2222222
    LubricantCode EK02
    Filling quantity 23x223x223x223x223x223x223x2
    FanType Spiral axial fan
    Qty.No.22242628283032
    CapacitykW39.643.246.850.450.454.057.6
    Air flow×104m3/h44485256566064
    Air side heat exchangerType Fins
    Densitypiece/inch16FPI
    Water side heat exchangerType Dry shell-tube type
    Water flow for coolingm3/h191.0206.7220.9235.1250.5266.3282.0
    Pressure drop of cooling waterkPa47546475844854
    Water flow for heating*m3/h198.2214.5229.2243.9258.0273.2288.5
    Pipe diameterinch8888888
    Heat exchanger at the heat
    recovery side
    Type Plate heat exchanger
    Water flowm3/h47.751.755.258.862.666.670.5
    Pipe diameterinch2222222
    Rated currentA673724775826829871913
    Startup currentA89396010281096109811531188
    Max. startup currentA1063106312151239124112411275
    DimensionsLengthmm10800117001260013500135001440015300
    Widthmm2260226022602260226022602260
    Heightmm2525252525252525252525252525
    Weight of a single indoor unitShipment of cooling only unitskg10820110601107511160115601166011720
    Operation of cooling only unitskg11140113801139511480119201202012080
    Shipment of heat pump unitskg11010112501129011390117901189011950
    Operation of heat pump unitskg11330115701161011710121501225012310

    Note:
    ■ Rated cooling work conditions: outdoor dry bulb: 35°C; outlet water temperature: 7°C; water flow 0.172m3/(h·kW).
    ■ Rated heating work conditions: outdoor dry/wet bulb: 7°C/6°C; outlet water temperature: 45°C; water flow 0.172m3/(h·kW).
    ■ Rated working conditions for partial heat recovery units: inlet/outlet hot water temperature 50°C/55°C; inlet/outlet temperature of chilled
    water: 12°C/7°C; ambient dry bulb temperature 35°C.
    ■ *Heating parameters marked with only apply to heat pumps units. Cooling only EKAS units do not have these parameters.
    ■ For on-site electric wiring, see the name plate or installation menu of the unit.


    Inheriting the supreme air cooling design from EK Italy and equipped with the leading-edge total heat recovery technology, environment friendly units of R407C series can provide hot water with a temperature as high as 65°C to meet the air conditioning and hot water requirements of hospitals, clubs, factories, and so on.


    More Energy Saving


    The heat recovery technology improves cooling efficiency, reduces power consumption, and extends the service life of a unit. The total heat recovery technology recovers all condensate heat, saves power consumed by the fan of the heat exchanger at the air side, and reduces energy consumption by more than 15%.


    One Unit for Three Purposes


    One unit can be used for three purposes: cooling, heating, and free hot water. The unit can provide hot water with a temperature up to 65°C to meet guest house showering, kitchen cleaning, and factory hot water consumption requirements, thus saving investment in hot water equipment.


    Less CO2 and More Environment Friendly


    EK air conditioners feature a leading-edge total heat recovery technology to use waste heat, greatly save energy, and effectively mitigate the heat island effect in cities due to waste heat dissipation.


    Easy Installation


    The unit can be easily installed outside and requires no dedicated equipment room or operator. Free hot water is available as long as you connect the hot water pipes.

    Quality R407C Screw Air Cooled Heat Recovery Unit With Spiral Axial Fan 85 - 470 Tons for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)