    Brand Name : EuroKlimat
    Model Number : EKDW-V
    Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 5,000pcs per month
    Delivery Time : 15 working days after received your payment
    • Product Details
    • Company Profile

    Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation

    EK keeps looking for valuable distributors and partners around international markets…


    Vertical type cabinet F7 filter 4/6 rows coil air handling units with 30/50 mm PU insulation


    EUROKLIMAT possesses the most advanced technologies and manufacturing facilities/processes in the air conditioning sector and has been forging ahead at the forefront of air conditioning products and technologies for more than 40 years by enterprising innovation.

    Launched by EK to meet market demand, EKDW series air handling units feature joggle structures and foamed polyurethane plates for effective heat preservation and service life enhancement. Units of this series have 40 models and 560 standard specifications available for your choice, and can be widely used in central air conditioning systems of hotels, shopping malls, hospitals, office buildings etc.


    Functional section


    Mixing
    Primary efficiency filter

    Cooling coil

    Heating coil

    Wet film humidifier
    Electric heater
    Bag-type filter with medium efficiency

    Fan


    Specifications


    ModelEKDW
    040V
    EKDW
    050V
    EKDW
    060V
    EKDW
    070V
    EKDW
    080V
    EKDW
    090V
    EKDW
    100V
    EKDW
    120V
    EKDW
    135V
    EKDW
    150V
    Nominal air flow (m3/h)40005000600070008000900010000120001350015000
    External residual pressure (Pa)I80808080808080~~~
    II150150150150150150150150150150
    III220220220220220220220220220220
    IV300300300300300300300300300300
    Nominal cooling capacity (kW)4 rows of coils (return air)233037445056.363748495
    4 rows of coils (fresh air)55708394111121137167190202
    6 rows of coils (return air)3240475362697896112120
    6 rows of coils (fresh air)7086103122137156172206230264
    Nominal heating capacity (kW)4 rows of coils (return air)405060718291102122139155
    4 rows of coils (fresh air)658298115129148164197222246
    6 rows of coils (return air)4860728497108121142161178
    6 rows of coils (fresh air)7794113132152169191224257280
    Nominal cooling water flow (L/S)4 rows of coils (return air)1.101.431.762.102.802.683.003.524.004.52
    4 rows of coils (fresh air)2.623.333.954.485.295.766.527.959.059.62
    6 rows of coils (return air)1.521.902.242.522.953.293.714.575.335.71
    6 rows of coils (fresh air)3.334.104.905.816.527.438.199.8110.9512.57
    Nominal heating water flow (L/S)4 rows of coils (return air)0.961.211.451.711.982.192.462.943.343.74
    4 rows of coils (fresh air)1.571.982.362.773.113.563.964.755.345.93
    6 rows of coils (return air)1.161.451.742.022.342.602.923.433.874.29
    6 rows of coils (fresh air)1.862.272.733.173.674.064.615.406.186.75
    CoilTypeCopper tube with a new type of wavy aluminum fins
    Piece/inch13
    Working pressure (MPa)1.6
    Size of inlet/outlet water
    pipe connector
    R 1-1/2R 1-1/2R 1-1/2R 2R 2R 2R 2R 2R 2R 2-1/2
    Size of condensate water
    pipe connector
    R1-1/4
    FanType/materialHigh-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates
    TransmissionV-belt transmission
    Fanning directionTop
    MotorPower supply380V/3~/50Hz
    Type3-phase asynchronous motor; insulation grade of F and protection grade of IP54
    Motor power (kW)I

    0.75

    (0.75)

    0.75

    (1.1)

    1.1

    (1.1)

    1.1

    (1.1)

    1.1

    (1.5)

    1.5

    (1.5)

    1.5

    (2.2)

    ~~~
    II

    0.75

    (1.1)

    1.1

    (1.1)

    1.1

    (1.5)

    1.1

    (1.5)

    1.5

    (1.5)

    1.5

    (2.2)

    2.2

    (2.2)

    2.2

    (2.2)

    2.2

    (3.0)

    3.0

    (3.0)

    III

    1.1

    (1.1)

    1.1

    (1.1)

    1.5

    (1.5)

    1.5

    (1.5)

    1.5

    (2.2)

    2.2

    (2.2)

    2.2

    (2.2)

    2.2

    (3.0)

    3.0

    (3.0)

    3.0

    (4.0)

    IV

    1.1

    (1.5)

    1.1

    (1.5)

    1.5

    (2.2)

    1.5

    (2.2)

    2.2

    (2.2)

    2.2

    (3.0)

    2.2

    (3.0)

    3.0

    (3.0)

    3.0

    (4.0)

    4.0

    (4.0)

    FilterTypeThickness (mm)
    Thickness (mm)8/21
    CabinetType30mm-thick double-layer plates filled with polyurethane material foamed under high pressure for heat
    preservation
    Unit
    Dimensions
    Length (mm)920103012001230128012901330144015801870
    Width (mm)650650650810810810900900900810
    Height (mm)1270133513851490155016101800186018601680
    Unit weight4 rows of coils (kg)172203236274306323386423435482
    6 rows of coils (kg)179211246286321339404444458507

    ModelEKDW
    180V
    EKDW
    200V
    EKDW
    220V
    EKDW
    250V
    EKDW
    270V
    EKDW
    300V
    EKDW
    350V
    EKDW
    400V
    EKDW
    450V
    Nominal air flow (m3/h)180002000022000250002700030000350004000045000
    External residual pressure (Pa)I~~~~~220220220220
    II150150150150150300300300300
    III220220220220220400400400400
    IV300300300300300500500500500
    V~~~~~~600600600
    Nominal cooling capacity (kW)4 rows of coils (return air)115123138157170191220256286
    4 rows of coils (fresh air)246272302342369418481558620
    6 rows of coils (return air)142160173197211239276318354
    6 rows of coils (fresh air)317350379428454526596686754
    Nominal heating capacity (kW)4 rows of coils (return air)187202230255275310358408460
    4 rows of coils (fresh air)293326362406439502574656730
    6 rows of coils (return air)215238266300325366424484542
    6 rows of coils (fresh air)339377418474507574666766854
    Nominal cooling water flow (L/S)4 rows of coils (return air)5.485.866.577.488.109.1010.4812.1913.62
    4 rows of coils (fresh air)11.7112.9514.3816.2917.5719.9022.9026.5729.52
    6 rows of coils (return air)6.767.628.249.3810.0511.3813.1415.1416.86
    6 rows of coils (fresh air)15.1016.6718.0520.3821.6225.0528.3832.6735.90
    Nominal heating water flow (L/S)4 rows of coils (return air)4.514.875.556.156.637.488.649.8411.10
    4 rows of coils (fresh air)7.077.868.739.7910.5912.1113.8515.8217.61
    6 rows of coils (return air)5.195.746.427.247.848.8310.2311.6813.07
    6 rows of coils (fresh air)8.189.0910.0811.4312.2313.8516.0718.4820.60
    CoilTypeCopper tube with a new type of wavy aluminum fins
    Piece/inch13
    Working pressure (MPa)1.6
    Size of inlet/outlet water
    pipe connector
    R 2-1/2R 2-1/2R 3R 3R3R3R3R3R3
    Size of condensate water
    pipe connector
    R1-1/4
    FanType/materialHigh-efficiency forward-pitched centrifugal fans with multiple wings/zinc-plated steel plates
    TransmissionV-belt transmission
    Fanning directionTop
    MotorPower supply380V/3~/50Hz
    Type3-phase asynchronous motor; insulation grade of F and protection grade of IP54
    Motor power (kW)I~~~~~7.5(7.5)7.5(11)11(11)11(11)
    II4.0(4.0)4.0(4.0)4.0(5.5)4.0(5.5)5.5(5.5)7.5(7.5)11(11)11(11)11(15)
    III4.0(4.0)4.0(5.5)5.5(5.5)5.5(5.5)5.5(7.5)11(11)11(11)15(15)15(15)
    IV4.0(5.5)5.5(5.5)5.5(7.5)5.5(7.5)7.5(7.5)11(11)11(15)15(15)15(15)
    V~~~~~~15(15)15(15)15(18.5)
    FilterTypeThickness (mm)
    Thickness (mm)8/21
    CabinetType30mm-thick double-layer plates filled with polyurethane material foamed under high pressure
    for heat preservation
    Unit
    Dimensions
    Length (mm)206022502310248026302770277029303090
    Width (mm)8109009009009001010101010101170
    Height (mm)174018601920199019902270259027502810
    Unit weight4 rows of coils (kg)537649674779807968104011961384
    6 rows of coils (kg)5676827108208511021109912671461

    Note:
    ■ The above parameters are for standard units. However, EK can customize these parameters to meet special requirements from customers.
    ■ Working conditions for cooling under nominal return air flow: dry bulb 27°C, wet bulb 19.5°C; working conditions for cooling under nominal fresh air flow: dry bulb 34°C, wet bulb 28°C; water temperature under nominal cooling capacity: inlet water 7°C, outlet water 12°C.
    ■ Working conditions for heating under nominal return air flow: dry bulb 21°C; Working conditions for heating under nominal fresh air flow: dry bulb 0°C; water temperature under nominal heating capacity: inlet water 60°C, outlet water 50°C.
    ■ Weight listed in the above table are net weight of units. Operation weight may post an increase of 20%.
    ■ Parameters inside ( ) are the power of units with 6 rows of coils.
    ■ The coil loops for units with full return air ("R") and units with full fresh air ("F") may be different. Please specify the inlet air conditions while placing orders. EK can provide computer-aided model selection to
    meet special requirements. For detailed


    Aluminum Filter

    ■ Used to filter large particles, such as smog;
    ■ The aluminum frame helps to reduce maintenance cost;
    ■ The precision aluminum screen is easy to install and clean.

    Electronic Purification Apparatus


    ■ A high-voltage static dedusting technology is applied to effectively filter all sorts of dust, bacteria,
    virus and harmful gas;
    ■ Multi-layered filtering provides multi-layered protection;
    ■ A modular design can meet various air flow requirements.

    Photocatalyst Ultraviolet Sterilamp


    ■ The sterilamp can effectively dampening the growth of bacteria and mildew and thereby
    eliminating odor caused by such growth;
    ■ The photocatalyst itself is stable and unconsumed, and therefore can be effective for a long
    time;
    ■ The sterilamp can effectively degrade contaminants such as formaldehyde, toluene and
    ammonia into harmless and nontoxic materials, and does not cause secondary contamination.

    Wet film humidifier

    Tap water purified by the solenoid valve flows directly into the water distributor at the top of the
    humidifier through water pipes and then flows down to wet the wet film under the pull of gravity.
    Residual water collected by the water collector flows into the sewage through the drainpipe (water
    will not be recycled). Hot air passing through the wet film is dampened and cooled (equal enthalpy
    wetting). During this course, some water in the wet film is evaporated without consuming additional
    energy. The work principle of wet film humidifier with direct water flow is shown in the figure on the
    right side.

    Quality Energy Saving Fresh Industrial Air Handling Units With 30/50 mm PU insulation for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)