Direct Expansion(DX) Ceiling / Floor Standing Air Handling Units 37.5-125 KW

Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
Contact Now
    Buy cheap Direct Expansion(DX) Ceiling / Floor Standing Air Handling Units 37.5-125 KW from wholesalers
     
    Buy cheap Direct Expansion(DX) Ceiling / Floor Standing Air Handling Units 37.5-125 KW from wholesalers
    • Buy cheap Direct Expansion(DX) Ceiling / Floor Standing Air Handling Units 37.5-125 KW from wholesalers

    Direct Expansion(DX) Ceiling / Floor Standing Air Handling Units 37.5-125 KW

    Ask Lasest Price
    Brand Name : EuroKlimat
    Model Number : EKDX
    Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 5,000pcs per month
    Delivery Time : 15 working days after received your payment
    • Product Details
    • Company Profile

    Direct Expansion(DX) Ceiling / Floor Standing Air Handling Units 37.5-125 KW


    37.5-125 KW Direct expansion Air Handling Unit 30/50 mm PU insulations


    Features of EK clean-room air handling unit EK clean-room air handling unit is specifically designed for clean rooms. It provides a built-in cooling and heating source, integrates air handling and automatic control functions, and has the following features: low investment, simple system, efficient running, and easy installation and maintenance.


    ■ The unit has a simple design and easy control, and is suitable for independent use.


    ■ The indoor unit can be directly mounted to the ceiling or in an attached room, not requiring a special air-conditioner room.


    ■ No chilled or cooling water system is required. The control is simple. The project can be completed phase by phase at a low construction cost.


    ■ The maintenance is simple. Maintenance of a single unit requires only the space of the clean room.


    ■ The unit can run at temperature ranging from -10°C to 48°C.


    Specifications


    ModelIndoor unitEKDX150-37.5A/ EKDX150-37.5AR

    EKDX150

    -75A/

    EKDX150

    -75AR

    EKDX200

    -50A/

    EKDX200

    -50AR

    EKDX200

    -100A/

    EKDX200

    -100AR

    EKDX250

    -62A/

    EKDX250

    -62AR

    EKDX250

    -125A/

    EKDX250

    -125AR

    Outdoor unitEKAA150AB/ EKAA150ARB

    2xEKAA

    150AB/
    2xEKAA

    150ARB

    2xEKAA

    100AB/
    2xEKAA

    100ARB

    4xEKAA

    100AB/
    4xEKAA

    100ARB

    2xEKAA

    125AB/
    2xEKAA

    125ARB

    4xEKAA

    125AB/
    4xEKAA

    125ARB

    Nominal cooling capacity (1)kW37.5755010062125
    Nominal heating capacity (1)kW41.382.55511068137.5
    Nominal cooling capacity (2)kW32.5654484.558104
    Nominal heating capacity (2)kW3671.5499363114
    Air flowm3/h150001500020000200002500025000
    EKDM air handling unit model corresponding to the external height and width EKDM0910HEKDM0910HEKDM1011HEKDM1011HEKDM1013HEKDM1013H
    Refrigerant model R22,R410A
    Outer dimensions of indoor unitLengthmmAs per the number of function sections
    Heightmm149014901650165016501650
    Widthmm165016501810181021302130
    Outer dimensions of outdoor unit
    (W × D × H)
    mm

    1290x840

    x1840

    2x1290x840

    x1840

    2x990x840

    x1840

    4x1290x840

    x1840

    2x1290x840

    x1840

    4x1290x840

    x1840

    Compressor of outdoor unitModelFully hermetic volute
    Outdoor unit weightkg285 / 3002x285 / 2x3002x265 / 2x2804x265 / 4x2802x270 / 2x2854x270 / 4x285
    Power supply of outdoor unit 380V/3N~/50HZ
    Cooling input power of outdoor unitkW16.13 / 17.4732.26 / 34.9420.41 / 20.1740.82 / 40.3424.2 / 24.548.4 / 49.0
    Heating input power of outdoor unitkW-- / 14.7-- / 29.4-- / 20.3-- / 40.6-- / 20-- / 40
    Connecting pipe
    specifications
    Liquid pipeφmm(in.)15.88(5/8)15.88(5/8)15.88(5/8)15.88(5/8)15.88(5/8)15.88(5/8)
    Gas pipeφmm(in.)34.9(1-3/8)34.9(1-3/8)28.6(1-1/8)28.6(1-1/8)28.6(1-1/8)28.6(1-1/8)
    Connect mode Soldering

    Note:
    ■ The nominal cooling capacity (1) is measured under the following conditions: The indoor dry/wet bulb reads 27/19 °C and the outdoor dry/ wet bulb reads 35/24 °C. The nominal heating capacity (1) is measured under the following conditions: The indoor dry bulb reads 20 °C and the outdoor dry/wet bulb reads 7/6 °C.


    ■ The nominal cooling capacity (2) is measured under the following conditions: The indoor dry/wet bulb reads 24/17 °C and the outdoor dry/wet bulb reads 35/24 °C. The nominal heating capacity (2) is measured under the following conditions: The indoor dry bulb reads 24 °C and the outdoor dry/wet bulb reads 7/6 °C.


    ■ The nominal cooling capacity does not consider heat losses of the fan motor of the indoor unit. The external static pressure can be customized, in which case the power of the air supply motor changes accordingly.


    ■ The specifications are subject to change due to product improvements without prior notice.


    ■ The fresh air flow of the unit cannot be larger than 20%.


    Consolidated Structure


    The unit features a compact structure, easy assembly, and solid seal. It adopts special seal glue handling, providing air leakage rate as low as 0.3%. The 30mm (standard)/50mm (optional) enhanced high-pressure non-fluorine polyurethane double-layer foamed panel delivers a solid insulation performance and high bearing capacity, meeting requirements of a purifying unit for high residual pressure.


    High Efficient and Low Noise


    The outdoor unit adopts brand-name fully hermetic volute compressors that deliver high efficiency, low noise, and strong resistance to hydraulic shock and run at temperature ranging from -10°C to 48°C, meeting cleaning requirements in various regions and scenarios.


    The indoor unit adopts imported high-quality centrifugal fans with double air intakes (model selection of the fans has passed AMCA certification) or unhoused fans (optional), and is equipped with dedicated anti-vibration measures for quiet running.


    Load Matching


    The evaporation section of the indoor unit can be equipped with a bypass valve. The direct evaporation coil supports combination with multiple cooling capacity options according to different conditions for a wide range of fresh air/air return scenarios. The outdoor unit of a large-capacity cooling unit adopts modular design, allowing differential energy regulation during use, lowering the operating cost, and reducing shock on the grid at startup.


    Sterilization


    The indoor unit adopts a dry water drainage tray that has no residual condensed water and prevents bacteria. A stainless steel water tray is optional. In addition, a sterilization device such as efficient UV sterilization lamp and ozone generator can be configured as required to eliminate bacteria and effectively
    suppress microbes in the system.


    Saving Investment


    The unit has a built-in cooling and heating source and does not require a chilled or cooling water system, greatly saving user investment, and making the unit structure simple and compact. No dedicated equipment room is required. The unit can run immediately after cabling and piping. The installation, use, and maintenance are easy.


    Smart Control


    The unit adopts integrated digital electromechanical design and is equipped with a smart controller, providing multiple control functions such as constant temperature, constant humidity, function setting, fault alarm, and remote monitoring to ensure safe and reliable unit running.


    Prevention of Cold Bridge


    The unit adopts inner skeleton design and high-strength foam seals and tight repair door structure, effectively preventing cold bridge between wall plates, between wall plate and inner skeleton,
    or at the repair door. The panel of the unit is wrapped with solid insulating UPVC plastic at all sides, avoiding direct contact with thermal conductive parts, providing T1 class insulation performance, eliminating cold bridge, and preventing cooling loss.


    High-Quality Filters


    The unit adopts a high-quality multi-level (primary, medium, sub-high, and high efficiency) air filtering system. The filtering class meets the requirements of a special clean room, and can effectively suppress organic compounds on the filtering paper.


    Purification Design


    A special frame structure ensures smooth surface in the unit. The inner stainless steel surface and an efficient heat exchanger (optional) made of hydrophilic aluminum foil can effectively prevent dust accumulation and re-entrainment. The special design and materials can resist disinfectant and air erosion and are favorable for regular cleaning and sterilization.


    Multi-System Design


    The outdoor unit adopts modular design and starts level by level, efficiently reducing shock on the grid. Multiple levels of cooling are provided, allowing differential energy regulation under different load conditions and reducing the operating cost. The compressors wear in a balanced manner, prolonging the lifecycle.

    Quality Direct Expansion(DX) Ceiling / Floor Standing Air Handling Units 37.5-125 KW for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)