    Ask Lasest Price
    Brand Name : EuroKlimat
    Model Number : EKSW-V
    Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 5,000pcs per month
    Delivery Time : 15 working days after received your payment
    • Product Details
    • Company Profile

    Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW


    Vertical Cabinet-type Chilled Water Return Air Handling Unit


    Specifications


    Unit Model

    EKSW

    040V

    EKSW

    050V

    EKSW

    060V

    EKSW

    080V

    EKSW

    100V

    EKSW

    120V

    EKSW

    150V

    EKSW

    180V

    EKSW

    200V

    EKSW

    250V

    Nominal air flow (m3/h)4000500060008000100001200015000180002000025000
    External total pressure (Pa)I8080808080-----
    II150150150150150150150150150150
    III220220220220220220220220220220
    IV300300300300300300300300300300
    Nominal cooling capacity (kW)Four rows of coils (in air return condition)23323652608091118127154
    Four rows of coils (in fresh air condition)516978113130180209261278331
    Six rows of coils (in air return condition)2940456476102119146159188
    Six rows of coils (in fresh air condition)658898145170223257325349429
    Nominal heating capacity (kW)Four rows of coils (in air return condition)3849568499128151188205249
    Four rows of coils (in fresh air condition)597889132157202241299325405
    Six rows of coils (in air return condition)46576795115138167208226288
    Six rows of coils (in fresh air condition)7092107153186233284344376471
    Nominal cold water flow (L/S)Four rows of coils (in air return condition)1.101.521.712.482.863.814.335.626.057.33
    Four rows of coils (in fresh air condition)2.433.293.715.386.198.579.9512.4313.2415.76
    Six rows of coils (in air return condition)1.381.902.143.053.624.865.676.957.578.95
    Six rows of coils (in fresh air condition)3.104.194.676.908.1010.6212.2415.4816.6220.43
    Nominal hot water flow (L/S)Four rows of coils (in air return condition)0.921.181.352.032.393.093.644.544.956.01
    Four rows of coils (in fresh air condition)1.421.882.153.183.794.875.817.217.849.77
    Six rows of coils (in air return condition)1.111.381.622.292.773.334.035.025.456.95
    Six rows of coils (in fresh air condition)1.692.222.583.694.495.626.858.309.0711.36
    CoilModelHigh-quality air conditioner copper tubes are connected to
    hyperbolic aluminum plate-fins through mechanical expanding.
    Heat exchanger12
    Working pressure (MPa)1.6
    Inlet/outlet pipe connector sizeR1-1/2R1-1/2R1-1/2R2-1/2R2-1/2R2-1/2R2-1/2R2-1/2R2-1/2R2-1/2
    Condensed water pipe connector sizeR1-1/4
    FanType/materialEfficient centrifugal forward curved fan/galvanized steel plate
    Transmission modeV-belt transmission
    Air supply direction of the fanTop air supply
    MotorPower supply380V/3~/50H
    ModelTri-phase asynchronous motor, F-rate insulation, and IP54 protection
    Motor power (kW)I0.75(1.1)0.75(1.1)1.1(1.5)1.5(1.5)2.2(2.2)-----
    II1.1(1.1)1.1(1.1)1.5(1.5)1.5(1.5)2.2(3.0)2.2(2.2)3.0(4.0)4.0(4.0)4.0(5.5)5.5(5.5)
    III1.1(1.1)1.1(1.1)1.5(2.2)1.5(2.2)3.0(3.0)2.2(3.0)4.0(4.0)4.0(4.0)5.5(5.5)5.5(7.5)
    IV1.1(1.5)1.5(1.5)2.2(2.2)2.2(2.2)3.0(3.0)3.0(3.0)4.0(5.5)4.0(5.5)5.5(7.5)7.5(7.5)
    Unit noise (dB(A))I5860616263-----
    II59616263646365697071
    III60626364656466707172
    IV61636465666567717273
    FilterModelPrimary nylon filter
    Thickness (mm)21
    BoxModelThe internal of the environment-friendly galvanized steel plate is
    attached with efficient insulation sound-proof PE material.
    Unit Outer DimensionsLength (mm)937113711371352135217761776212621262478
    Width (mm)587657657738738958958957957957
    Height (mm)1162132213221678167820382038207220722193
    Unit weight (kg)Four rows of coils135185188265269440450556571665
    Six rows of coils146199202285289473483589613716

    Note:
    ■ The preceding parameters apply to the standard model. EK provides customized design to meet special requirements.
    ■ Nominal air return cooling condition: 27°C (dry bulb)/19.5°C (wet bulb). Nominal fresh air cooling condition: 34°C (dry bulb)/28°C (wet bulb). Nominal cooling water inlet/outlet temperature: inlet
    7°C; outlet 12°C.
    ■ Nominal air return heating condition: 21°C (dry bulb). Nominal fresh air heating condition: 0°C (dry bulb). Nominal heating water inlet/outlet temperature: inlet 60°C; outlet 50°C.
    ■ The unit weight listed in the table is net weight. The operating weight increases by about 20%.
    ■ The value in brackets in the table indicates the motor power for a unit with 6 rows of coils.
    ■ The noise values in the preceding table are measured at a distance of 1 m from the unit in a state certified standard semi-anechoic room according to the GBT 9068-1988 standard.
    ■ If the external total pressure value of the unit used in model selection is large, the air flow will be large, leading to noise and water spray. Therefore, carefully determine the air duct resistance.
    ■ The coil loop form varies from a full air-return unit to a full fresh air unit. Mark the air inlet condition at purchase. Specify R for a full air-return unit and F for a full fresh air unit. EK provides model
    selection software for special requirements. For specific parameters, see the model selection result.



    The EKSW cabinet-type Air Handling unit is a product designed by EK air conditioner based on the air conditioner market and endpoint product features in China. The unit integrates a single-wall structure box, efficient forward fan, and fine processed coils. Secondary design is performed for the unit by using special EK air conditioner model selection software to better meet the requirements of customers for horizontal and vertical Air Handling units, saving indoor room. This product may widely apply to central air conditioner projects such as hotels, malls, airports, hospitals, factories, scientific research organs, and office buildings. It is especially applicable to scenarios with confined installation space and high requirements for noise such as reconstruction on obsolete buildings.


    Cutting-edge manufacturing techniques and production devices are used. High-quality air conditioner copper tubes are connected to hyperbolic hydrophilic aluminum plate-fins through mechanical expanding so that the copper tubes and fins match, achieving optimal heat exchange for coils and ensuring efficient running of the unit. Coils of different specifications and loop forms are available to provide optimal running solutions in all conditions and meet various Air Handling requirements for users. The unit has a high external total pressure, a large cooling capacity, a small volume, and a simple structure, facilitating installation and repair.


    Construction party


    Built-in unit terminal box and convenient external cable connection
    Wide maintenance manhole for easy repair
    Optional simple accessories such as temperature control and pressure difference alarm
    Installation is easy. Flanges are set at both air inlet and outlet for easy duct connection.
    The unit can be installed on floor or ceiling.

    Quality Vertical Cabinet Type Chilled Water Return Air Handling Unit 23-429KW for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)