    Brand Name : EuroKlimat
    Model Number : EKSW-H
    Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 5,000pcs per month
    Delivery Time : 15 working days after received your payment
    • Product Details
    • Company Profile

    Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil

    EK keeps looking for valuable distributors and partners around international markets…


    Horizontal Package Fresh Air Handling Unit 4/6 rows cooling Coil


    Specifications


    Unit ModelEKSW
    020H
    EKSW
    030H
    EKSW
    040H
    EKSW
    050H
    EKSW
    060H
    EKSW
    070H
    EKSW
    080H
    EKSW
    090H
    EKSW
    100H
    EKSW
    120H
    EKSW
    135H
    EKSW
    150H
    Nominal air flow (m3/h)2000300040005000600070008000900010000120001350015000
    External total pressure (Pa)I8080808080808080----
    II150150150150150150150150150150150150
    III220220220220220220220220220220220220
    IV300300300300300300300300300300300300
    Nominal cooling capacity (kW)Four rows of coils (in air return condition)12.018.825.931.936.943.950.055.461.676.280.690.9
    Four rows of coils (in fresh air condition)28.740.856.172.085.297.3110.0125.4139.3164.8174.8200.1
    Six rows of coils (in air return condition)15.923.732.740.149.855.863.572.478.094.7107.9115.5
    Six rows of coils (in fresh air condition)35.554.470.090.5109.9126.9136.6155.4176.6211.9235.8258.9
    Nominal heating capacity (kW)Four rows of coils (in air return condition)18.528.838.847.956.967.181.391.5101.6122.0135.7150.7
    Four rows of coils (in fresh air condition)30.644.860.576.492.8109.4127.9145.5161.6194.0211.2237.2
    Six rows of coils (in air return condition)23.034.346.457.769.980.796.4109.0119.9144.0162.7178.1
    Six rows of coils (in fresh air condition)36.454.972.491.4110.7129.2150.3170.0189.8227.8257.4287.2
    Nominal cold water flow (L/S)Four rows of coils (in air return condition)0.570.891.241.521.762.092.382.642.943.633.844.33
    Four rows of coils (in fresh air condition)1.361.942.673.434.064.645.245.976.637.858.329.53
    Six rows of coils (in air return condition)0.761.131.561.912.372.663.033.453.714.515.145.50
    Six rows of coils (in fresh air condition)1.692.593.344.315.246.046.507.408.4110.0911.2312.33
    Nominal hot water flow (L/S)Four rows of coils (in air return condition)0.440.690.921.141.351.601.942.182.422.903.233.59
    Four rows of coils (in fresh air condition)0.731.071.451.822.212.613.053.463.854.625.035.65
    Six rows of coils (in air return condition)0.550.821.101.371.661.922.302.592.853.433.874.24
    Six rows of coils (in fresh air condition)0.871.311.722.182.643.083.584.054.525.426.136.84
    Fins/inchModelHigh-quality air conditioner copper tubes are connected to
    hyperbolic aluminum plate-fins through mechanical expanding.
    Heat exchanger12
    Working pressure (MPa)1.6
    Inlet/outlet pipe connector sizeR1-1/2R1-1/2R1-1/2R2R2R2R2R2R2R2-1/2R2-1/2R2-1/2
    Condensed water pipe connector sizeR1-1/4
    FanType/materialEfficient centrifugal forward curved fan/galvanized steel plate
    Transmission modeEfficient V-belt transmission
    Air supply direction of the fanDownward horizontal
    MotorPower supply380V/3~/50H
    ModelTri-phase asynchronous motor, F-rate insulation, and IP54 protection
    Rated power
    of motor (kW)
    I

    0.37

    (0.37)

    0.55

    (0.55)

    0.55

    (0.75)

    1.1

    (1.1)

    1.1

    (1.1)

    1.1

    (1.5)

    1.1

    (1.1)

    1.1

    (1.5)

    ----
    II

    0.37

    (0.55)

    0.55

    (0.55)

    0.75

    (0.75)

    1.1

    (1.1)

    1.1

    (1.5)

    1.5

    (1.5)

    1.1

    (1.5)

    1.5

    (1.5)

    2.2

    (2.2)

    2.2

    (2.2)

    2.2

    (3.0)

    3.0

    (3.0)

    III

    0.55

    (0.55)

    0.55

    (0.75)

    0.75

    (1.1)

    1.1

    (1.5)

    1.5

    (1.5)

    1.5

    (2.2)

    1.5

    (2.2)

    1.5

    (2.2)

    2.2

    (2.2)

    2.2

    (3.0)

    3.0

    (3.0)

    3.0

    (3.0)

    IV

    0.55

    (0.55)

    0.75

    (0.75)

    1.1

    (1.1)

    1.5

    (1.5)

    1.5

    (2.2)

    2.2

    (2.2)

    2.2

    (2.2)

    2.2

    (2.2)

    2.2

    (3.0)

    3.0

    (3.0)

    3.0

    (3.0)

    3.0

    (4.0)

    Unit noise (dB(A))I5255575960626262----
    II535658606163636363626365
    III545759616264646464636466
    IV555860626365656565646567
    FilterModelPrimary nylon filter (connected through 8 mm hook)
    BoxModelThe galvanized steel plate applies static spraying and the internal is
    attached with efficient insulation sound-proof PE material.
    Unit Outer DimensionsLength (mm)109010901181138115811781167117711921203722372447
    Width (mm)83110511090109010901090118511851185123512351235
    Height (mm)505505570570570570670670670742742742
    Unit weight (kg)Four rows of coils7998118130152163194198217262287300
    Six rows of coils82102124136160172207212232280307322

    Note:
    ■ The preceding parameters apply to the standard model. EK provides customized design to meet special requirements.
    ■ Nominal air return cooling condition: 27°C (dry bulb)/19.5°C (wet bulb). Nominal fresh air cooling condition: 34°C (dry bulb)/28°C (wet bulb). Nominal cooling water inlet/outlet temperature: inlet
    7°C; outlet 12°C.
    ■ Nominal air return heating condition: 21°C (dry bulb). Nominal fresh air heating condition: 0°C (dry bulb). Nominal heating water inlet/outlet temperature: inlet 60°C; outlet 50°C.
    ■ The unit weight listed in the table is net weight. The operating weight increases by about 20%.
    ■ The value in brackets in the table indicates the motor power for a unit with 6 rows of coils.
    ■ The noise values in the preceding table are measured at a distance of 1 m from the unit in a state certified standard semi-anechoic room according to the GBT 9068-1988 standard.
    ■ If the external total pressure value of the unit used in model selection is large, the air flow will be large, leading to noise and water spray. Therefore, carefully determine the air duct resistance.
    ■ The coil loop form varies from a full air-return unit to a full fresh air unit. Mark the air inlet condition at purchase. Specify R for a full air-return unit and F for a full fresh air unit. EK provides model
    selection software for special requirements. For specific parameters, see the model selection result.


    Design


    Complete design parameters of the standard unit such as water flow and water pressure drop
    Comprehensive secondary design software
    Comprehensive non-standard design flow and wide application scope
    The proprietary integrated computer-based model selection software is specifically designed
    for EKSW units for model selection and matching. This software can flexibly and conveniently
    select proper units according to customer requirements and provide specific model selection
    results for customers.

    Purifying and sterilizing device (optional)


    Aluminum filter


    ■ It can filter out large granular dust such as lampblack.
    ■ The aluminum frame structure reduces the maintenance cost.
    ■ The precise aluminum mesh structure is easy to install and clean.Electric purifier
    ■ Using high-voltage static cleaning technology, it effectively eliminates dust, germs,virus, and harmful gases.
    ■ It provides multiple layers of protection by using multiple levels of filtering.
    ■ The modular combination design helps determine reasonable configuration according to the air flow.

    Photo catalyst ultraviolet lamp for sterilization

    ■ It effectively prevents germs and moulds on coils and eliminates smells that are thereby generated.
    ■ The photo catalyst does not suffer change or loss, and lasts long.
    ■ It can effectively decompose pollutants such as methanol, methylbenzene, and ammonia. It is not toxic or harmful, and does not produce pollution.


    Wet-film humidifier


    Clean running water that passes through the electromagnetic valve is sent to a water distributor at the top of the wet film over a water pipe. The water flows downwardly at the surface of the wet film under gravity to wet the surface of the wet film. The water that arrives at the water tray is discharged to the drainage pipe through a bent water drainage pipe. That is, the water is not recycled. When hot air passes through the humid wet film, its humidity increases and its temperature drops. This humidification
    process is called isoenthalpic humidification process. During this process, certain water on the wet film is evaporated, which does not consume extra energy. The working principle of wet-film direct
    drainage humidifier is shown in the figure on the right.

    Quality Horizontal Package Fresh Air Handling Unit 4/6 Rows Cooling Coil for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong EuroKlimat Air-Conditioning & Refrigeration Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)