    Brand Name : EuroKlimat
    Model Number : EKRV-ET
    Certification : ISO9001, ISO14001, OHSAS18001, CRAA, CQC
    Price : Negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 1500 units per month
    Delivery Time : 20 working days after received your payment
    • Product Details
    • Company Profile

    R410A Vrv Air Conditioning System For Home Low Energy Consumption Supercooling


    DC Inverter VRF Air Conditioner R410A 14 kW~357 kW


    Condensing Unit Cooling Capacity : 14KW-357KW

    Indoor Unit Type : Ceilling Concealed Ducted Type, High ESP Ducted Type , Fresh Air Duct Type , Wall Mounted Type ,4 Way Cassette type,1 Way Cassette type,2 Way Cassette,Ceiling/standing type.

    Indoor Unit Cooling Capacity :1HP~32HP


    Description:


    Higher Energy Efficiency


    By using a PWM valve to control the time ratio of unloading and loading status, the DC inverter scroll compressor can continuously regulate the capacity within a range of 10%–100%, increasing the precision of capacity regulation and the stability of indoor temperature.


    Low Energy Consumption


    The unit boasts an outstanding IPLV(C) (refrigerating coefficient of performance). The full series of units features an IPLV(C) that is far higher than China national standard energy efficiency level 1st.


    More Advanced Technologies


    Quick Start Technologies


    EKRV series DC Inverter multi-connected central air conditioners can run in full load within a short period, quickly meeting indoor requirements.


    Supercooling Technologies


    Enlarges the condenser of the outdoor unit to implement level-1 supercooling, and then uses an efficient supercooler to implement level-2 supercooling, reaching a total supercooling degree of 19.6°C. Enhances the cooling capability of the unit and improves the efficiency of the unit. Reduces the pressure loss when the refrigerant is circulated in the pipe, rationally allocating the ultra-long accessory pipe and refrigerant.


    DC inverter motor


    Fans of outdoor units can be regulated at 32 levels based on load changes, improving efficiency and reducing noise.


    The unit can safely run under partial load for a long time.


    Intelligent Defrosting Technologies;


    Wide operation range


    EKRV series digital multi-connected central air-conditioning units can generate cooling result in ambient temperature of 55°C.


    Ultra-long Connecting Pipe


    Total pipe length

    1000m

    Max. equivalent length of a single pipe

    220m

    Max. actual length of a single pipe

    190m

    Max. vertical span between outdoor and indoor units

    110m

    Max. vertical span between indoor units

    40m


    Easy Installation


    The system can provide an external static pressure of 50 Pa, ensuring the heat dissipation result of the outdoor unit under the same installation conditions (optional).

    A higher external static pressure ensures that the outdoor unit can be flexibly installed at a rooftop, compartment, balcony, or equipment floor, preventing overload of the unit due to poor ventilation


    More Secure


    Dual Backup Operation with Guaranteed Security

    Automatic Fault Diagnosis

    Technologies for Automatic Identification of Pipe Length

    Multiple Measures to Effectively Protect Compressors

    Door Card Function (Optional)

    Intelligent and Balanced Operation Management


    Electronic expansion valve


    The unit uses an electronic expansion valve with 4000-step capacity regulation to increase the precision of superheat degree control (liquid level control), enhance the operation security, and improve energy saving.


    More Intelligent


    Centralized Monitoring Software


    One set of EKRV centralized monitoring software can control up to 2048 indoor units, meeting customers' requirements for large-scale centralized management.


    Separate Control Charging per Customer


    The unit can fairly and rationally divide the electricity quantity based on the model, operation mode, operation time, air supply/ return efficiency, and refrigerant flow of the air conditioning unit to protect the rights and interests of all owners. The unit provides customers with functions such as owner management, price and recharge management, energy saving management.


    Centralized Control


    Models of indoor units are diverse for selection.


    Indoor units cover 6 series and 63 capacity types, and total fresh air indoor units are available, fully meeting customer requirements.


    More Environment-friendly


    Full Compliance with RoHS Directive,

    Environment-friendly Refrigerant,

    Automatic Refrigerant Recovery Technologies,

    Automatic Determination of Refrigerant Charge,

    Energy Consumption of 5 W in Standby Mode(a Record Low in the Industry)


    Applications


    hotels,entertainment centers, hospitals, restaurants, office buildings, cinemas,

    factories, school supermarkets and so on.


    Specifications


    ModelEKRV080ER1EKRV100ER1EKRV120ER1EKRV140ER1EKRV160ER1EKRV180ER1EKRV200ER1EKRV220ER1EKRV240ER1
    CapacityHP81012141618202224
    Power supply380-415V/3N~/50Hz
    Rated cooling capacitykW25.2283440455156.56268
    Rated heating capacitykW2831.537.54550.557636975
    Rated power of coolingkW5.856.98.6210.3712.2213.5515.0316.5517.24
    Rated power of heatingkW5.977.078.9610.7212.2513.6215.1216.7617.92
    Rated current of coolingA11.313.416.420.223.325.828.631.432.7
    Rated current of heatingA11.413.717.120.423.325.928.731.834
    Max working currentA22.524.925.839.140.345.247.148.651.6
    Liquid pipemm (inch)9.5212.715.88
    Gas pipemm (inch)19.0522.2325.428.6
    Pipe connectionLiquid pipeConnecting bell-mouthed terminal with threaded joint
    Gas pipeConnecting bell-mouthed terminal with threaded jointWelding
    Unit weightkg205215235315325345355365370
    Sound leveldB(A)565760606061616162
    RefrigerantR410A
    Dimensions (W x D x H)(mm)920×760×16401140×835×16401655×835×1640

    ModelEKRV260ER1EKRV280ER1EKRV300ER1EKRV320ER1EKRV340ER1EKRV360ER1EKRV380ER1EKRV400ER1EKRV420ER1
    CapacityHP262830323436384042
    Power supply380-415V/3N~/50Hz
    Rated cooling capacitykW747985.29096102108114119
    Rated heating capacitykW82.58895100.5107.5114120127.5133
    Rated power of coolingkW18.9920.8422.423.4525.7727.127.6129.3631.21
    Rated powerkW19.6821.2122.7323.8325.8727.2428.6430.431.93
    of heating
    Rated current of coolingA3639.542.544.548.951.452.455.759.2
    Rated current of heatingA37.340.243.145.249.151.754.357.760.6
    Max workingA64.966.171.173.575.578.585.59092.5
    current
    Liquid pipemm19.05
    Gas pipemm31.838.1
    Pipe connection modeLiquid pipeConnecting bell-mouthed terminal with threaded joint
    Gas pipeWelding
    Unit weightkg480485510515545550575580585
    Sound leveldB(A)626263636363636364
    RefrigerantR410A
    Dimensions (W x D x H) 1780×835×16402615×835×1640
    (mm)